Installation date: 2016
Down date: 2020
Still installed in Clean room
Problem discription: The tool failed optics qualification due to dead channel on CPC0.
Compared CPC-0 with CPC-1 and confirmed during TDI calibration CPC-0 detector has
abnormal pixel spike.
Error message: Illumination Profile Average Gain Out Of Range error.
Parts faulty identified:
1. CPC-0 P/N: 0676983-000 FRU ASSY,CPC ENCLOSURE GENE
2. POWER SUPPL P/N: 0356296-003 FRU ASSY,PWR SUPPLY,PS2,84VDC